reinforcing ground preparation water proofing grouts chemicals joints concrete repair reinforcing reinforcing accessories brickwork accessories formwork accessories
about us projects document downloads contacts how to find us a-z index hire kform kform  
prefab service
mesh fabric cut
dowels
mesh fabrics
reinforcing bar
steel bar
fence posts
clear
REINFORCING & PRE-FABRICATION
clear
 
BAR SHAPE CODES TO BS 8666:2005 clear Click here
for Tables
 
  Shape Code - Total length of bar (L) measured along centre line  
  41   2A + B + 2C + 1.5r - 3d
(C) and (D) shall be equal and
not more than A nor less than
P in Table 2. Where (C) and (D)
are to be minimized the following
formula may be used:
L = 2A + B + max (21d, 240)
 
  44   2 (A + B + (C)) - 2.5r - 5d
(C) and (D) shall be equal and
not more than A or B nor less
than P in Table 2. Where (C)
and (D) are to be minimized
the following formula may be
used: L = 2A + 2B + max
(16d, 160)
 
  46   A + B + C + (D) + 2(E) – 2.5r – 5d
(E) & (F) shall be equal and
not more than B or C, nor less
than P in Table 2
 
         
 
CODE 1 clear CODE 2 clear CODE 3 clear CODE 4 clear CODE 5 clear CODE 6
clear clear clear   clear   clear   clear   clear
CODE 7 clear CODE 8   CODE 9   CODE 10   CODE 11   NOTES
 
how to find us 1
document downloads
manufacturers
clear